We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: PCr/ATP ratio is determined at 7 T typically using Fourier-transform based magnetic resonance spectroscopic imaging sequences (FT-MRSI). These sequences require acquisition times longer than desirable for inclusion in cardiac clinical trials. Concentric ring trajectory (CRT-MRSI) has been described as an accelerated alternative k-space sampling method. In this work we aim to establish the inter- and intra-session repeatability of three different CRT protocols and compare their voxel-based PCr/ATP ratios to compartment-based PCr/ATP values extracted with spectroscopy using a linear algebraic model (SLAM) method. METHODS: Seven healthy volunteers were scanned twice on two different days. Each time a 6.5-min 3D FT-MRSI acquisition with 10 × 10 × 10 resolution was followed by a 2.5-min CRT-MRSI with matched resolution, a 1.5-min CRT-MRSI with matched resolution, and a 6.9-min CRT-MRSI with 12 × 12 × 12 resolution. Spectra from a mid-septal voxel and the cardiac compartment were fitted with the OXSA toolbox. PCr/ATP ratio was quantified for inter- and intra-session repeatability analysis. RESULTS: Paired repeated measurements were not significantly different within subjects. Good inter- and intra-session agreement was observed between FT-MRSI and each CRT-MRSI protocol. CRT-MRSI protocols all had larger coefficients of repeatability (CoR) than FT-MRSI. CRT-SLAM-based PCr/ATP values had lower CoR than voxel-based data except for 2.5-min CRT-SLAM, and high-resolution CRT-SLAM had lower inter-session CoR compared to FT-MRSI (1.42 vs. 2.21). CONCLUSION: We established the repeatability of CRT-MRSI-based PCr/ATP values and showed higher SNR and lower CoR for CRT-SLAM. Our findings allow shorter 31P MRS acquisition times and the use of more advanced energetics-probing techniques in clinical studies.

More information Original publication

DOI

10.1002/mrm.70220

Type

Journal article

Publication Date

2025-12-08T00:00:00+00:00

Keywords

31P spectroscopy, accelerated k‐space traversal, concentric ring trajectory, myocardial energetics